The EV battery system start-up capability testing is mainly to verify the EV battery system start-up output power at low temperature and low SOC.
The brief method of EV battery system start-up capability testing is as follows: perform a constant voltage discharge with a maximum current limit based on the maximum pulse discharge current specified by the battery cell manufacturer and collect the voltage U and current I at the end of the discharge pulse.
The low temperature start-up power output of an EV battery system can be calculated by the following two equations.
Calculation formula for average power of the Xth constant voltage discharge.
PX=(∑U*I)/n
Calculation formula for low temperature starting power.
P=(P1+P2+P3)/3
For EV battery system start-up capability testing, regenerative EV battery testing equipment and temperature cycle chamber are essential.
WinAck Group can provide complete EV battery testing equipment solutions. Come by, contact us for a solution that can help you succeed. For better batteries, Win & Ack!